Home » Product List » Patient Monitor » 12.1''Patient Monitor (LDM-G3D)
Product Details
12.1''Patient Monitor (LDM-G3D)
| Model NO.: | LDM-G3D |
|---|---|
| Standard: | 12.1" Safety standard: IEC 60601-1, CE, ISO |
| Productivity: | 10000/month |
| Unit Price/Payment: | T/T Paypal L/C |
| HS Code: | 90181930 |
| Trademark: | DEVONMED BRAND |
| Origin: | China |
| Min. Order: | on limited |
| Transportation: | DHL, UPS, TNT, EMS, Fedex, and Ocean Shipping |
Patient Monitor:
Model # LDM-G3D
Standard configuration:
ECG, HR, PR, SpO2, OxyCRG diagram, ST analysis, Arrhythmia analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation and lead-acid battery.
Physical Character:
1. Displayer: 12.1" color TFT LCD screen with maximum 8-waveform display.
2. Battery: Rechargeable high-energy built-in battery
3. Advanced streamline outline design, portable, compact, lightweight
4. Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, Arabic, Russian, Italian, etc.
5. Easy operation with user friendly menu structure design and rotary dial
6. Against & eliminate ESU interference & defibrillation, no need to disconnect the monitor from the patient in process of defibrillating.
7. Three-application mode: Monitoring, diagnosis, operating.
8. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
9. Optional built-in wireless networking function
10.72 hours data storage.
11. Intelligent audio and visual comprehensive alarm
12. In-hospital applications include emergency room's pre and post operative care, ICU, Operation room/theater, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.
13. Suitable for use in physicians' offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring
14. Suitable for adult, pediatrics, neonates
Accessories:
1 set of ECG cable
1 set of ECG electrode
1 set of NIBP extend cable
1 set of NIBP adult or pediatric or neonate cuff
1 set of RESP nasal cavity pipe
1 set of TEMP surface probe
1 set of TEMP cavity probe
1 set of integrated adult or pediatric or neonate SpO2 sensor
1 set of power supply cable
Optional configuration:
Wireless networking function to patient monitor;
Inside placed thermal-sensitive built-in printer;
IBP function (Include 1 pressure sensor and 1 adaptable cable);
ETCO2 function module(Include 1 disposable dehydration bottle);
Wall Mount for patient monitor;
Trolly for patient monitor;
12 volts Power supply for ambulance
| √-- Temperature (surface and rectal) Measurement range: 25.0 – 45.0 C Accuracy: +/- 0.1 C Resolution: 0.1 C response time: =< 3 min. √ ---ECG : Input: 5 wires ECG cable Lead section: I,II,III/ aVR, aVL, aVF/ V Gain ( mm/mV ) : 1/4 , 1/2 , 1 , 2 ,4 Frequency response : Diagnosis 0.05 - 100Hz Monitor 0.5 - 40 Hz Surgery 1.0 - 25 Hz Sweep speed(mm/sec): 12.5, 25, 50 Heart rate range: 30-254 BPM Heart rate accuracy: +/- 1 % ST segment deviation analysis: -0.8-+0.8mV ST accuracy: +/-0.02mv √ ---Respiration Rate : ( RALL impedance and nasal cavity) Measurement range: 0 - 120 BPM(adult ) Accuracy: +/-1 BPM or 5 % Resolution: 1 BPM √---Power requirements : Input: 98 - 260 V AC, 50/60Hz Consumption: =< 80VA √---Environment : Operation Storage Temperature 0.5 - 40 C -20 - 50 C Relative humidity =< 80% | √----Pulse Rate : SPO2 measurement range: 0 - 100 % Resolution: 1 % Pulse measurement range: 30- 254BPM Accuracy: +/- 2 % Resolution: 1 BPM √----NIBP (Non-invasive blood pressure) Measurement type : adult, pediatric, neonatal Measurement range: Systolic 4.0 - 37.0 kPa Diastolic 1.3 - 33.0 kPa Mean 2.6 - 35.0 kPa Accuracy : +/- 0.4 kPa or 5 % Resolution: 0.1 kPa Protection: over pressure √----IBP(Invasive blood pressure) (with venous punch) (Option) Measurement range: -1.3~40kPa (-10~300mmHg) Channel: 2 channel Transducer sensitivity: 5MV/V/mmHg Unit display: KPa or mmHg selectable √----ETCO2 (side stream type) (Option) Measurement range:0-10 % (ins CO2 and et CO2) Accuracy:+/- 2 mm Hg (< 5 % Measurement value) 10 % (> 5 % Measurement value) Response time: 180 Ms =< 90% Safety standard: IEC 60601-1 Quality System : ISO13485: 2003 |
Inquiry Basket (