Add to Basket 12.1''Patient Monitor (LDM-G3D)

Model NO.: LDM-G3D
Standard: 12.1" Safety standard: IEC 60601-1, CE, ISO
Productivity: 10000/month
Unit Price/Payment: T/T Paypal L/C
HS Code: 90181930
Trademark: DEVONMED BRAND
Origin: China
Min. Order: on limited
Transportation: DHL, UPS, TNT, EMS, Fedex, and Ocean Shipping
Product Description

Patient Monitor:

Model # LDM-G3D

Standard configuration:
ECG, HR, PR, SpO2, OxyCRG diagram, ST analysis, Arrhythmia analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation and lead-acid battery.

Physical Character:

1. Displayer: 12.1" color TFT LCD screen with maximum 8-waveform display.
2. Battery: Rechargeable high-energy built-in battery
3. Advanced streamline outline design, portable, compact, lightweight
4. Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, Arabic, Russian, Italian, etc.
5. Easy operation with user friendly menu structure design and rotary dial
6. Against & eliminate ESU interference & defibrillation, no need to disconnect the monitor from the patient in process of defibrillating.
7. Three-application mode: Monitoring, diagnosis, operating.
8. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
9. Optional built-in wireless networking function
10.72 hours data storage.
11. Intelligent audio and visual comprehensive alarm
12. In-hospital applications include emergency room's pre and post operative care, ICU, Operation room/theater, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.
13. Suitable for use in physicians' offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring
14. Suitable for adult, pediatrics, neonates

Accessories:
1 set of ECG cable
1 set of ECG electrode
1 set of NIBP extend cable
1 set of NIBP adult or pediatric or neonate cuff
1 set of RESP nasal cavity pipe
1 set of TEMP surface probe
1 set of TEMP cavity probe
1 set of integrated adult or pediatric or neonate SpO2 sensor
1 set of power supply cable

Optional configuration:
Wireless networking function to patient monitor;
Inside placed thermal-sensitive built-in printer;
IBP function (Include 1 pressure sensor and 1 adaptable cable);
ETCO2 function module(Include 1 disposable dehydration bottle);
Wall Mount for patient monitor;
Trolly for patient monitor;
12 volts Power supply for ambulance

√-- Temperature (surface and rectal)

Measurement range: 25.0 – 45.0  C 
Accuracy: +/- 0.1 C 
Resolution: 0.1  C 
response time: =< 3 min. 

√ ---ECG :
Input:  5 wires ECG cable 

Lead section: I,II,III/ aVR, aVL, aVF/ V 
Gain ( mm/mV ) : 1/4 , 1/2 , 1 , 2 ,4
Frequency response : 
                      Diagnosis 0.05 - 100Hz 
                           Monitor 0.5 - 40 Hz 
                           Surgery 1.0 - 25 Hz 

Sweep speed(mm/sec): 12.5, 25, 50 
Heart rate range: 30-254 BPM 
Heart rate accuracy: +/- 1 % 
ST segment deviation analysis: -0.8-+0.8mV
 ST accuracy: +/-0.02mv
 
√ ---Respiration Rate :
( RALL impedance and nasal cavity) 

Measurement range: 0 - 120 BPM(adult ) 
Accuracy: +/-1 BPM or 5 % 
Resolution: 1 BPM 

√---Power requirements :
Input: 98 - 260 V AC, 50/60Hz 
Consumption: =< 80VA 

√---Environment  :
                         Operation   Storage 
Temperature 0.5 - 40 C  -20 - 50 C Relative humidity =< 80% 
 
√----Pulse Rate  :

SPO2 measurement range: 0 - 100 % 
Resolution: 1 % 
Pulse measurement range: 30- 254BPM 
Accuracy: +/- 2 % 
Resolution: 1 BPM 

√----NIBP (Non-invasive blood pressure) 

Measurement type : adult, pediatric, neonatal 
Measurement range: Systolic 4.0 - 37.0 kPa 
                                       Diastolic 1.3 - 33.0 kPa 
                                       Mean 2.6 - 35.0 kPa 
Accuracy : +/- 0.4 kPa or 5 % 
Resolution: 0.1 kPa 
Protection: over pressure 

√----IBP(Invasive blood pressure) 

(with venous punch) 
(Option) 
Measurement range: -1.3~40kPa (-10~300mmHg) 
Channel: 2 channel 
Transducer sensitivity: 5MV/V/mmHg 
Unit display: KPa or mmHg selectable 

√----ETCO2 (side stream type) (Option) 

Measurement range:0-10 % (ins CO2 and et CO2)
Accuracy:+/- 2 mm Hg (<  5 % Measurement value) 
                              10 % (>  5 % Measurement value) 
Response time: 180 Ms =< 90% 
Safety standard:  IEC 60601-1 
Quality System : ISO13485: 2003  
                         